项目 |
KLC-FFU1220 |
KLC-FFU610 |
KLC-FFU915 |
||||||
型号 |
AZ-WF305 |
AZ-WF355 |
EBM |
AZ-WF305 |
AZ-WF250 |
AZ-WF305 |
AZ-WF355 |
EBM |
|
数量(台) |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
电源 |
220V/50Hz |
220V/50Hz |
220V/50Hz |
220V/50Hz |
220V/50Hz |
220V/50Hz |
220V/50Hz |
220V/50Hz |
|
功率(W) |
125 |
160 |
180 |
125 |
160 |
125 |
160 |
180 |
|
转速(r/min) |
1395 |
1370 |
1400 |
1395 |
2185 |
1395 |
1370 |
1400 |
|
风量(m³/h) |
1260 |
1960 |
2580 |
1260 |
1100 |
1260 |
1960 |
2580 |
|
噪音(dB) |
<=58 |
<=58 |
<=58 |
<=58 |
<=58 |
<=58 |
<=58 |
<=58 |
|
面风速(m/s) |
平均风速>=0.45m/s |
平均风速>=0.45m/s |
平均风速>=0.45m/s |
||||||
外形尺寸(mm) |
1225×615×350 |
615×615×350 |
920×615×350 |
||||||
高效 |
尺寸(mm) |
1220×610×69 |
610×610×69 |
915×610×69 |
|||||
效率(%) |
99.99%@0.3µm |
99.99%@0.3µm |
99.99%@0.3µm |
||||||
风量(m³/h) |
2000 |
1000 |
1500 |
||||||
初阻力(Pa) |
<=220 |
<=220 |
<=220 |
||||||
初效 |
尺寸(mm) |
445×445×21 |
445×445×21 |
445×445×21 |
|||||
效率级别 |
G3 |
G3 |
G3 |
||||||
效率 |
75% |
75% |
75% |
||||||
初阻力(Pa) |
30 |
30 |
30 |
||||||
板材 |
材质 |
A3冷板/不锈钢 |
A3冷板/不锈钢 |
A3冷板/不锈钢 |
|||||
厚度(mm) |
1.2/1.0 |
1.2/1.0 |
1.2/1.0 |
1.净化级别:静态100级;
2.风速为:0.2-0.5m/s,噪音≤60dB,电源为220V,50Hz。;
3.无隔板高效过滤器,过滤效率为:99.99%,确保净化级别;
4.整体采用冷钢板酸洗静电喷塑;
5.无级调速设计,调速性能稳定,在高效过滤器终阻力的状态下仍能保证风量不变;
6.选用台湾高效离心式风机,寿命长、低噪声、免维护、震动小,且提供两年质保;
7.特别适合组装成超净生产线,可根据工艺需要布置为单台使用,也可以渐多台串联成100级流水装配线。FFU设有初、高效两级过滤网。风机从FFU顶部将空气吸入并经初、高效过滤器过滤,过后的洁净空气在整个出风面以0.45M/S±20%的风速匀速送出。采用美国,适用于在各种环境中获得别的洁净环境。它为不同尺寸大小,不同洁净度等级的洁净室、微环境提供高质量的洁净空气。在新建洁净室、洁净厂房式改造翻新中,即可提高洁净度级别,降低噪音和振动,也可大大降低造价,安装维护方便,是洁净环境的理想部件。
FFU产品特点是高度低,系统设计时可节省气室空间。轻量化结构设计,可符合各厂家的Grid 系统安装,更可依 Grid 系统,变更 FFU 结构尺寸设计。内部装置扩散板.风压扩散均匀,出风面风速平均稳定。金属结构顺风道内胆,老化.杜绝二次污染产生,表面光滑,风阻低.隔音效果优良。特殊入风口,风道设计,降低压损与噪音的产生。马达效率高,系统消耗电流低,节省能源成本。单相马达,提供三段式调速,可依实际状况调高或降低风速与风量。